Energy concept
![]() |
![]() |
| U-value W/m2K | |
| Extern wall | 0.18 - 0.26 |
| Roof | 0.12 - 0.16 |
| Window / glass | 0.9 / 0.7 |
The total energy use of the buildings is calculated with: 33 W/m²BGF (LEK
value of 21-22).
On the roofs 380 m² solar panels are mounted - used for domestic hot water and
additional input in the heating system.
The heating is a biomass district heating system. Two 150 kW
wood-pellets-heaters heat the water in a 40 m³ puffer tank. This is situated as
an own building in front of one house.
Each dwelling has a controlled air-ventilation system with heat recovery.
In a special research program the SIR (Salzburger Institut für Raumordnung und
Wohnen) in Salzburg measures four dwellings exactly from the energy-consumption,
air-quality and the different temperatures.
To use the modern technology and optimize the indoor quality and energy
consumption all tenants have got a special brochure about the heating and
air-ventilation system. On two information evenings interested people were
informed about the technique and how to optimize the energy use and energy
saving in a household. Interested tenants could visit the solar panels on the
roof and the heating room in the cellar.